You're not logged in!
Username:

Password:

Remember Me?



 Users Online
Members Online:
 Statistics
702 registered members,
527 topics in forums,
2616 posts in forums,
2406454 pages served since 2004-07-09.
 Join Chat Room
 
E.O.P.A
 Weather Forecast
Weather Forecast
Weather Forecast
 Statistics

ACPB T-shirt
15.00 USD

 View Shouts
Comm.Johnson: There will be no game Sunday a handful of us are goin to represent EOPA in Connecticut. See everyone in 2 weeks
Comm.Johnson: wheres everyone been. Summer yas say its to hot winters here and now what too cold?
Comm.Johnson: Game Sunday New Years day 10am @ EOPA field
jgacs: Whats up!!
Just stopin by
Comm.Johnson: Merry Christmas Everyone.
Comm.Johnson: there will be a game here on Sunday December 4th. Anyone still interested in Seek the jersey game let me know i have passes
Sergio: Hi, r u guys playing this sunday 11.27. ?
 
 bigtankchris  
 ronamyth  
 didomia  
 tacoma?  
 Sergio  
 View All
 
 
01-26 07:55 1. Public » New Users » Yea..Im a Noob (2)
11-11 15:45 1. Public » New Users » Russians.. (1)
09-24 16:21 1. Public » General discussion » Hello, (10)
 
None
 
Tank hydrotest
News | Date: 01-25-2008 | Author: | Comments: (0)
All tanks must be periodically retested depending on the material and size.
Steel tanks must be hydrotested every five years. All fiber-wrapped tanks must be hydrotested every three or five years, depending on the DOT-E regulation (see below). If you are unsure, assume the tank requires testing every three years. The only exception is for tanks that are less than two inches in diameter and less than two feet in length, which never require retesting.


Steel and aluminum tanks never expire; the tank is good as long as it pasts the hydrotesting. Fiber-wrapped tanks, however, are only good for 15 years maximum. After that, the tank must be retired.
The only exception is steel tanks marked 3HT, which must be hydrotested every three years, and expire after 24 years.
This applies to both CO2 and HPA tanks.




DOT-Exeption / DOT-Special Permit (DOT-E / DOT-SP):
All fiber-wrapped tanks are marked with a specific DOT exception regulation on the label. Recently this was switched to special permit and marked with DOT-SP, but the same regulations apply. This regulation is a code that denotes information on the tank's testing status, depending on who manufacturered it.
These tanks are three-year:

- E-07277 (manufacturered by SCI)
- E-09634 (Luxfer)
- E-12479 (Luxfer)
- E-11005 (Carleton)


Here are a list of "extended" tanks. These tanks have a cutoff date for hydrotesting. If the tank was last tested before that date, it is still on the three-year hydrotest schedule. If the tank was last tested after the cutoff date, it will then be on the five-year hydrotest schedule.

- E-10915 (Luxfer) - cutoff date 05-11-2001
- E-10945 (SCI) - cutoff date 07-01-2001
- E-11194 (Carleton) - cutoff date 07-01-2001

Carleton tanks are used by Crossfire, Pure Energy, Smart Parts, and others. Older Pure Energy tanks used Luxfer tanks. SCI tanks can be found on WGP, ACI Bulldog, some Crossfire, and others.

Tank hydrodating is there for a reason.
Filling it after the expried date is dangerous and illegal.

You must ALWAYS obey all tank hydrostatic regulations.